Tag Mapping
Wire each OEE pillar to the live tag values that drive it. Three input groups, three input modes per slot.
The Tag Mapping tab on an Equipment tells the OEE engine which tag carries which signal. Every input slot accepts the same three input modes, so once you’ve learned the pattern on one slot it works the same way everywhere else.

The three input groups
Each group is independent — you can wire only the tags the pillars you’ve enabled actually need. A field that’s required by validation has a red asterisk and shows a tooltip identifying it; optional fields can stay empty.
The Select Tag Mapping dialog
Click the Configure button to open the tag dialog:

The dialog has two top-level tabs:
Single Tag — pick a single tag from one of the available Asset Hierarchies, then choose how the value should be interpreted (Direct or, for string tags, JSONata).
Calculation — combine multiple tags into one signal using a variable-based expression. See Calculations.
The currently active tab determines the mapping type stored on the slot:
Single Tag (Direct)
Direct
None — the source tag’s value is used as-is.
Single Tag (Accumulating)
Accumulating
Roll-over value (e.g. 65536 for a 16-bit counter) — the engine reports the delta between successive readings, handling roll-over automatically.
Single Tag (Jsonata)
JsonataExpression
A JSONata value expression plus optional start/end timestamp expressions.
Calculation
SymbolicExpression
A list of (symbol → tag) variables and an arithmetic expression like a+b/c.
Single Tag — Direct vs. Accumulating
After you select a tag in the Single Tag tab, a Value Parser pane appears below the grid. For numeric (analog/digital) tags it offers two options:
Direct
The tag already emits the signal you want — a state code, an instantaneous count, a percentage. The engine uses every reading as-is.
Accumulating
The tag is a free-running counter (cycle count, units produced) that resets at a known Roll Over Value (e.g. 65536). The engine reports the delta between successive readings, handling roll-overs automatically.
Pick Accumulating when the value the tag emits is monotonic-with-roll-over and you actually want the change between readings — typical for produced-unit counters off a PLC.

The delta is calculated as:
delta = current − previouswhencurrent ≥ previous(normal increment).delta = (RollOverValue − previous) + currentwhencurrent < previousand a Roll Over Value is configured (counter wrapped past its max).delta = currentwhencurrent < previousand no Roll Over Value is configured (treated as a counter reset).
Set the Roll Over Value to match the counter’s width (e.g. 65536 for a 16-bit counter, 4294967296 for a 32-bit counter) so wraps are credited correctly. Leave it empty for counters that you know reset to 0 explicitly (e.g. at start of shift) — the engine then treats every backward jump as a reset.
Single Tag — JSONata for string tags
If the selected tag has a String measurement type — typical when an MQTT or OPC tag carries a JSON payload — the Value Parser switches to a JSONata editor:
Direct
The tag value is exactly the string you want (e.g. Running already).
Jsonata
The tag carries a structured payload and you want to extract a field from it. Write a JSONata expression that resolves to the value to use.
For interval-mode error codes and order tags (see State & Error Codes and Product & Order), the JSONata pane also exposes optional Start Timestamp and End Timestamp expressions so you can pull the interval bounds out of the same payload.
The Open Query Editor button opens the JSONata Query Window with the source tag’s example payload pre-populated (for MQTT topics that have one configured) so you can iterate on the expression with example preview before saving.

Calculation — variables + expression
When no single tag carries the signal you need, switch to the Calculation tab in the Select Tag Mapping dialog. You define one or more named variables (a, b, c, …) each pointing at a tag, then write an arithmetic / boolean expression that evaluates to the signal value.
The same engine drives the Equation data connector — the Operators and Functions reference pages list everything you can use.
See Calculations for the full procedure including Validate and Evaluate.
Tooltips for every field
Every input on the Tag Mapping tab has a tooltip, that describes the purpose a use. Click it to view a detailed description.
What each pillar needs (summary)
Availability
Equipment Run State
Error Code (and Error Code Closed in Event Pair mode)
Performance
Current Product Id, Ordered Products, order-completion event (see below)
—
Quality
Two of: Products Total, Products Approved, Products Rejected (the third is derived), plus order-completion event (see below)
—
Performance and Quality both require an order-completion event because their count tags are aligned to orders by exact timestamp match. Configure Order Id in Single Event (start & end) mode (with an end-timestamp expression) or Order Start + Order End in Event Pair mode. See Aligning counts with order completion.
If a pillar is disabled on the Equipment tab, its tag fields are not required even if they’re shown.